1. What is the reason for the failure to load or the communication failure?

The reasons for communication failure and loading failure are roughly the same, which may be caused by the following reasons. Please compare the listed items and operations:

1) Ensure that the control system hardware has been powered on correctly. (+5V)

2) Check and confirm that the serial cable used to connect to the controller is a straight-through cable, not a crossover cable.

3) Check and confirm that the serial port cable is intact and there is no looseness or falling off at both ends.

4) Compare the LED screen control software and the control card you choose to select the correct product model, correct transmission method, correct serial port number, correct serial transmission rate, and correctly set the control according to the DIP switch diagram provided in the software The address bit and serial transmission rate on the system hardware.

5) Check whether the jumper cap is loose or falling off; if the jumper cap is not loose, make sure that the direction of the jumper cap is correct.

6) If it still fails to load after the above inspection and calibration, please use a multimeter to measure whether the serial port of the connected computer or control system hardware is damaged to confirm whether it should be returned to the computer manufacturer or the control system hardware The body is returned for testing.


2. Why does the LED screen appear bright lines for a few seconds or the screen picture becomes blurred when it is first powered on?

After the screen controller is properly connected to the computer and the HUB distribution board and the screen, you need to provide +5V power to the controller to make it work normally (at this time, do not directly connect to the 220V voltage).

At the moment of power-on, a bright line or "fuzzy screen" will appear on the screen for a few seconds. This bright line or "fuzzy screen" is a normal test phenomenon and reminds the user that the screen is about to start working normally. Within 2 seconds, the phenomenon will be automatically eliminated, and the screen will enter the normal working state.


3. What does automatic or manual brightness adjustment mean?

Brightness adjustment refers to the adjustment made between the darkest and brightest that the screen can display, not the sensitivity adjustment. Automatic brightness adjustment is automatically adjusted to a predetermined brightness by the wide LED screen control system according to the different brightness that should appear in different time periods. Manual brightness adjustment refers to the operation of the LED screen control system by the end user to make the LED screen reach a certain specified brightness.


4. The whole screen of the unit board is not bright, dark and bright

1) Visually check whether the power connection cable, the 26P cable between the unit boards and the power module indicator are normal.

2) Use a multimeter to measure whether the unit board has normal voltage, and then measure whether the voltage output of the power module is normal, if not, it is judged that the power module is broken.

3) Measure the low voltage of the power module and adjust the fine adjustment (the fine adjustment of the power module near the indicator light) to make the voltage reach the standard.


5. What is the reason why the LED screen appears completely black?

In the process of using the control system, we occasionally encounter the phenomenon that the LED screen appears completely black. The same phenomenon may be caused by a variety of different reasons, even the process of turning the screen black will vary with different operations or different environments.

For example, it may be black the moment it is powered on, it may turn black during the loading process, or it may turn black after sending it, etc.:

1) Please make sure that all hardware including the control system has been powered on correctly. (+5V, do not connect reversely or wrongly)

2) Check and confirm whether the serial port cable used to connect to the controller is loose or falling off. (If it turns black during the loading process, it is probably caused by this reason, that is, the communication line is interrupted due to the loosening of the communication line during the communication process, so the screen becomes black. Please check it yourself, this is very important if you want to solve the problem quickly.)

3) Check and confirm whether the HUB distribution board connected to the LED screen and the main control card is tightly connected and whether it is plugged in reverse.


Introducing Our Team

MileStrong has an experienced technical and sales team with over 10 years of experience in LED display technologies and project support. Through hands-on experience with diverse LED display projects and complex installation requirements, our team has developed extensive technical expertise. We are committed to providing professional support throughout every stage of your project, from product selection and solution development to installation and after-sales service.

Send Inquiry